The noise reduction coefficient (NRC) is a single number that tells you how much sound a material absorbs when sound hits its surface. It runs from 0, a hard surface that reflects almost everything, to about 1, a surface that absorbs almost everything that reaches it. NRC describes absorption inside a space: echo, reverberation and how “live” a room sounds. It does not describe how much sound passes through a wall or a booth panel. That is the job of sound transmission ratings such as STC.
Last Updated: November 19, 2026 | Author: Richard

What an NRC rating tells you
An NRC rating is the average of a material’s sound absorption coefficients at four mid frequencies: 250, 500, 1000 and 2000 Hz. Each coefficient is the share of incident sound energy the material absorbs at that frequency, so an NRC of 0.70 means the material absorbs roughly 70% of mid-frequency sound that strikes it and reflects the rest.
A few practical readings of the scale:
- Around 0.05: painted drywall, glass, concrete and similar hard finishes. They reflect nearly all speech energy back into the room.
- 0.50 to 0.75: many standard acoustic ceiling tiles and thin fabric-covered panels.
- 0.85 and above: thick porous absorbers such as fabric-wrapped fiberglass or dense polyester fiber panels, especially with an air gap behind them.
NRC can exceed 1.00. ASTM notes that coefficients for highly absorptive specimens may exceed unity. This happens because of edge diffraction during the test, not because the panel absorbs more sound than reaches it. Treat 1.05 and 1.00 as the same class of performance.
How NRC is measured under ASTM C423
In the United States, NRC comes from ASTM C423, the test method for sound absorption by the reverberation room method. The current edition is ASTM C423-23e1; the 2023 edition was approved on April 15, 2023.
The test works like this:
- A lab measures how quickly sound decays in an empty reverberation room, a large chamber with hard, non-parallel surfaces.
- A specimen, typically about 8 ft by 9 ft for panel products, is installed and the decay is measured again.
- The extra absorption the specimen adds is converted into absorption coefficients for one-third-octave bands from 100 Hz to 5000 Hz.
- For NRC, the coefficients at 250, 500, 1000 and 2000 Hz are averaged and rounded to the nearest 0.05.
Mounting changes the result. C423 requires the specimen to be mounted the way it will be installed, and ASTM E795 defines the standard mountings, from a panel laid directly on a hard surface to panels spaced away from it with an air cavity behind. The same panel can test higher with an air gap, mainly in the lower bands. An NRC figure without its mounting is incomplete.
Outside the United States, labs often test to ISO 354, the international reverberation room method. It produces the same kind of one-third-octave absorption coefficients. ISO 354 itself does not define NRC, so when a report from an ISO 354 test quotes an NRC, the lab has applied the NRC averaging to its ISO data.
NRC vs SAA: which number to read
Since its recent editions, ASTM C423 makes the sound absorption average (SAA) the primary single-number rating. SAA averages twelve one-third-octave bands from 200 to 2500 Hz and rounds to the nearest 0.01. C423 keeps NRC so that new results stay comparable with decades of published data.
| NRC | SAA | |
|---|---|---|
| Frequencies used | 250, 500, 1000, 2000 Hz | 12 one-third-octave bands, 200 to 2500 Hz |
| Rounding | Nearest 0.05 | Nearest 0.01 |
| Status in ASTM C423 | Legacy rating, still reported | Primary single-number rating |
| Best use | Comparing with older product data | Finer comparison between similar products |
Both numbers skip the low end. A panel can post a high NRC and still absorb little at 100 or 125 Hz, where HVAC rumble and traffic noise sit. If low-frequency sound is part of the problem, read the full frequency table, not the single number.
NRC vs STC (and NIC)
NRC and STC answer different questions, and confusing them is the most common mistake buyers make when comparing acoustic products.
| NRC | STC | NIC | |
|---|---|---|---|
| Question it answers | How much sound does this surface absorb? | How much airborne sound does this partition block in the lab? | How much sound is blocked between two spaces as built? |
| What is tested | A material or product surface | A wall, door or panel assembly | An installed room or enclosure |
| Typical standard | ASTM C423 (ISO 354 internationally) | ASTM E90 test, ASTM E413 rating | ASTM E336 field test, ASTM E413 rating |
| Scale | About 0 to 1 | A dB-based class, higher is better | A dB-based class, higher is better |
| Fixes | Echo, reverberation, noise build-up inside a room | Sound passing through a partition | Real-world privacy between spaces |
A thick foam panel can have an NRC near 1.0 and do almost nothing to stop a voice from passing through a wall, because it is light and porous. A heavy, sealed wall can have a high STC and still leave the room behind it echoing. Most spaces that need privacy and comfort need both: mass and seals to block sound, and absorptive finishes to control what stays inside. For a deeper look at transmission ratings and why a lab STC differs from installed performance, see our guide to STC ratings for office phone booths.

NRC targets for office spaces
Office design standards set NRC targets for ceilings, because the ceiling is the largest surface available for absorption. The WELL Building Standard sets these minimums:
- Open offices: NRC 0.9 or higher over the entire ceiling area, excluding lights, diffusers and grilles.
- Conference and teleconference rooms: NRC 0.8 or higher on at least 50% of the ceiling area.
WELL draws these values from the U.S. General Services Administration’s Sound Matters guide. They are a useful reference for what “highly absorptive” means in office terms: a finish at NRC 0.9 or above sits in the top band of commonly specified ceiling products.
If your office needs acoustic treatment on walls rather than ceilings, our article on office acoustic panels covers placement and the problems panels can and cannot solve.
What NRC means inside an office phone booth
A phone booth or office pod uses two acoustic layers that do different jobs:
- The shell blocks sound. Panels, glass, door seals and the ventilation path decide how much speech leaks out and how much office noise gets in. In B&H pods, each wall panel is a composite of seven material layers, with the absorptive lining as its inner face. Blocking is a transmission question, measured for complete pods with ISO 23351-1 or with sound level difference tests.
- The interior lining absorbs sound. A booth is a small, closed box. Without absorption, the occupant’s voice reflects off hard walls and glass, the space sounds boxy on calls, and sound energy builds up inside. A high-NRC lining keeps the interior acoustically “dry”, which helps call clarity and comfort.
The lining NRC therefore tells you about the experience inside the booth. It does not, on its own, tell you how private the booth is. For privacy, look at a whole-pod result. For example, Elite-S achieved ISO 23351-1 Class A acoustic performance with 33 dB speech level reduction. In B&H office testing under controlled conditions, Elite-S showed a 40-45 dB sound level difference. Our explainer on ISO 23351-1 and what 33 dB means shows how that whole-pod test works.
Example: reading B&H’s lining absorption report
Every B&H pod is lined with a polyester fiber acoustic board. A sample of the board was tested in an independent acoustics laboratory in April 2024 under ISO 354 (sound absorption by the reverberation room method):
- Sample: 9 mm polyester fiber acoustic board, 1.85 kg/m², 10.8 m² test area
- Mounting: supported on a wood frame with a 200 mm (about 7.9 in) air space behind it
- Reported single-number ratings: NRC 0.91; average absorption coefficient 0.80 across 100 Hz to 5 kHz
Selected one-third-octave coefficients from the report:
| Frequency (Hz) | 125 | 250 | 500 | 1000 | 2000 | 4000 |
|---|---|---|---|---|---|---|
| Absorption coefficient | 0.28 | 0.99 | 1.07 | 0.80 | 0.96 | 1.06 |
This report is a good example of the details worth checking in any NRC data:
- The single number depends on the averaging rule. The lab reports NRC 0.91. Applying the ASTM C423 arithmetic to the four center bands in the same table (250, 500, 1000 and 2000 Hz) gives 0.95, and an SAA over the twelve bands from 200 to 2500 Hz gives 0.89. When you compare two products, compare the same rating calculated the same way, or compare the frequency tables directly.
- The mounting is part of the result. This board was tested with a 200 mm air space, which favors absorption in the lower bands. Inside B&H pods the board is fixed directly to the wall panel with no cavity, so the in-pod values in the lower bands sit below this lab table. When you compare suppliers, ask which mounting their data reflects.
- The low end is shown, not hidden. Absorption is 0.11 at 100 Hz and 0.28 at 125 Hz, then jumps near 1.0 from 250 Hz up. The single NRC never shows this; the table does.
How to read an NRC test report
Use this checklist when a supplier sends absorption data for a panel, ceiling tile or booth lining:
- Test standard and edition. ASTM C423 or ISO 354, with the year. A reverberation room method is the norm for NRC; impedance tube results (ASTM C384) are not interchangeable with room results.
- Independent laboratory. The report should name the lab, the report number and the test date, and the lab should be accredited for the method.
- Exact specimen. Material, thickness and density or surface weight. A 9 mm board and a 25 mm board of the same material are different products.
- Mounting. Directly on a hard surface, or spaced with an air cavity, and how deep. This often explains differences between two “identical” panels.
- The full frequency table. Look at 125 Hz and below if low-frequency noise matters, and check whether values above 1.00 are pulling the average up.
- Which single number. NRC, SAA, or a lab-specific average. Confirm how it was calculated before comparing it with another product.
- What the number is used for. An absorption report supports claims about echo and reverberation. It does not support claims about sound blocking or speech privacy; those need STC, NIC or a whole-enclosure test.
FAQ
Is a higher NRC always better?
For a surface whose job is absorption, yes, up to a point. Differences of about 0.05 to 0.10 are hard to hear in practice, so a 0.85 and a 0.90 panel will sound much alike. Coverage matters as much as the rating: a small area of 0.95 material does less than a whole ceiling at 0.80.
Can NRC be higher than 1.0?
Yes. Reverberation room results for thick or highly absorptive specimens can exceed 1.00 because sound diffracts around the specimen edges during the test. Read anything above 1.00 as “absorbs essentially all incident mid-frequency sound”.
What NRC should an office phone booth interior have?
ASTM and ISO do not set a booth-specific NRC. A practical reference point is the NRC 0.9 that WELL requires for open-office ceilings, which marks a highly absorptive finish. For a buying decision, pair the lining data with a whole-pod sound reduction result, and compare models in our office phone booth range by both.