
Wheelchair accessible office pods
ADA Office Pods with Roll-In Entry for Wheelchair Users
Flex-L ADA and Flex-XL ADA are built without a pod floor. The walls stand on your finished floor, so a wheelchair user rolls straight in through a 35.4-inch clear door and has room to turn around inside.
For meetings of more than six people, the Aura Room-in-Room meeting room is also floorless, from 3 × 3 m upward.
Quick answer
For a wheelchair user, an office pod has to provide step-free entry, a door with at least 32 inches of clear width, and a 60-inch turning space inside, the core room dimensions in the 2010 ADA Standards. B&H Ergonomics builds two floorless sizes that meet them: Flex-L ADA (86.6 × 66.9 in footprint, 2–4 people) and Flex-XL ADA (98.4 × 86.6 in, 4–6 people), each with a 35.4-inch clear door and one wheelchair position among the seats. For meetings of more than six people, choose an Aura Room-in-Room in 3 × 3, 4 × 4, or 5 × 4 m.
ADA pod sizes
Flex-L ADA and Flex-XL ADA dimensions and seating
Both models are Flex Series pods built to order without a floor. Use the exterior size to place the pod on your floor plan and the interior floor size to check turning space and furniture. Flex-L ADA, the smaller size, also works as a single-user ADA privacy booth for calls and focused work.
| Specification | Flex-L ADA | Flex-XL ADA |
|---|---|---|
| Exterior (W × D × H) | 86.6 × 66.9 × 88.6 in (2200 × 1700 × 2250 mm) | 98.4 × 86.6 × 88.6 in (2500 × 2200 × 2250 mm) |
| Interior floor (W × D) | 81.3 × 61.6 in (2064 × 1564 mm) | 93.1 × 81.3 in (2364 × 2064 mm) |
| Clear door opening | 35.4 in (900 mm) | 35.4 in (900 mm) |
| Entry | No pod floor and no threshold; walls fixed to the finished floor | No pod floor and no threshold; walls fixed to the finished floor |
| Seating | 2–4 people, including one wheelchair position | 4–6 people, including one wheelchair position |
| Sound privacy | In B&H office testing under controlled conditions, Flex-L ADA showed a 36-40 dB sound level difference. | In B&H office testing under controlled conditions, Flex-XL ADA showed a 36-40 dB sound level difference. |
| Control panel and outlets | Height set to order; recommended 15–48 in above the floor | Height set to order; recommended 15–48 in above the floor |
Interior floor sizes are the exterior size minus the 68 mm (2.7 in) Flex wall on each side.
Step-free entry
Roll-in entry with no pod floor
Standard B&H pods stand on their own floor, which adjustable feet raise 40–90 mm (1.6–3.5 in) on the M size. Flex-L ADA and Flex-XL ADA leave that floor out. The walls stand directly on the finished floor and are fixed to it with screws, so the surface inside the pod is the office floor itself, with no threshold at the door.
The 2010 ADA Standards cap a doorway threshold at 1/2 inch (Section 404.2.5). With no pod floor, there is no threshold or ramp to measure.
- Floor surface: the existing floor becomes the pod floor, so it should be stable, firm, and slip resistant, as Section 302.1 requires.
- Screw fixing: confirm with the building owner that the floor can take the fixings, especially in a leased office.
- Door: a 35.4 in (900 mm) clear opening on both models, above the 32 in minimum in Section 404.2.3.

Measured against the ADA Standards
How Flex-L ADA and Flex-XL ADA measure against the 2010 ADA Standards
The 2010 ADA Standards for Accessible Design set the dimensions an accessible room is reviewed against. The table compares the ones that apply inside and at the door of a pod.
| ADA requirement | Section | Flex-L ADA | Flex-XL ADA |
|---|---|---|---|
| Door clear width: 32 in minimum | 404.2.3 | 35.4 in | 35.4 in |
| Turning space: 60 in circle, or a T-shape within a 60 in square | 304.3 | 61.6 in interior depth; the circle fits with about 0.8 in to spare on each side | 81.3 in interior depth |
| Threshold: 1/2 in maximum | 404.2.5 | None; no pod floor | None; no pod floor |
| Controls and outlets: 15–48 in above the floor | 308.2.1, 308.3.1 | Height set to order | Height set to order |
| Wheelchair space: 30 × 48 in clear floor space | 305.3 | Marked at the table on the layout drawing | Marked at the table on the layout drawing |
Need a different footprint?
Flex ADA pods are built to order. Send the space you have, and B&H Ergonomics will size the pod around the turning circle and door clearance.
Inside the pod
Sound privacy, controls, and comfort
The floorless build changes the entry. The rest of the pod is specified like any Flex Series pod.
Sound privacy
In B&H office testing under controlled conditions, Flex-L ADA and Flex-XL ADA each showed a 36-40 dB sound level difference.
Control panel and outlets
Heights are set to your order. B&H Ergonomics recommends placing them 15–48 in above the floor, the forward and side reach range in Sections 308.2.1 and 308.3.1.
Power
110V Plug & Play power with UL Listed Components.
Light and air
Built-in LED lighting and ventilation fans.
Finishes
Choose from 9 standard exterior colors or a custom exterior from 216 RAL colors, plus 48 interior colors in fabric or easy-clean laminated steel.
Warranty
A 3-year limited warranty overall. Ventilation fans are covered for 2 years, and electrical components and LED lighting for 1 year.
For larger teams
Aura Room-in-Room: wheelchair accessible meeting rooms for larger teams
When a meeting group is larger than six, a meeting room fits better than a pod. Aura Room-in-Room is a glass-walled meeting room from the B&H Ergonomics Aura Series, shaped with large-radius rounded corners. Like the Flex ADA pods, it has no floor of its own: it stands directly on the office floor, so wheelchair users roll in at floor level.
| Size | Footprint | Typical use |
|---|---|---|
| 3 × 3 m | 9 ft 10 in × 9 ft 10 in | Focus room or small huddle room |
| 4 × 4 m | 13 ft 1 in × 13 ft 1 in | Team collaboration and meetings |
| 5 × 4 m | 16 ft 5 in × 13 ft 1 in | Larger teams, workshops, and multi-use meetings |
- Height: 88.6 in (2250 mm), with a full-height 88.6 in door.
- Sound: 32 dB sound reduction in every size.
- Turning space: even the 3 × 3 m size leaves far more floor than a 60-inch turning circle needs.
- Custom sizes: width, depth, and corner radius are built to your floor plan.
- Built in: ventilation, lighting, and power.
Finishes and layouts are in the Aura Room-in-Room brochure (PDF).
Choose the format
Which accessible format fits your group
Start from the number of people who meet at once, including the wheelchair user.
Project review
What your ADA review will check around the pod
Accessibility is reviewed for the installed space, including the route to the pod and the furniture inside it. Bring these points to your architect or the authority having jurisdiction (AHJ).
Route to the door
Keep an accessible route at least 36 in wide to the pod (Section 403.5.1).
Door approach
Leave maneuvering clearance on both sides of the door for the approach direction and door swing (Section 404.2.4).
Turning space
Keep the 60 in circle or T-shaped space clear inside once the furniture is placed (Section 304.3).
Table and seating
Choose a work surface 28–34 in high (Section 902.3), with a 30 × 48 in clear floor space at the table (Section 305.3).
Controls and outlets
Set the control panel and outlets 15–48 in above the floor (Section 308).
Fire, electrical, and air
Check sprinkler, electrical, and ventilation requirements with the guide to office pod fire safety, UL documentation, and AHJ review.
For the background on turning circles, T-turns, and accessible meeting layouts, see what makes an ADA room accessible.
ADA pod quote
Request an ADA pod quote
Tell B&H Ergonomics who will use the space and where it will stand. The quote confirms the model, size, furniture, and control heights for your project.
Delivered DDP to the Lower 48 states, with 110V Plug & Play power and UL Listed Components.
Request an ADA Pod QuoteInclude these details
- City and state for delivery.
- Number of users and wheelchair positions.
- Floor plan, or the available width and depth.
- Flex-L ADA, Flex-XL ADA, or an Aura Room-in-Room size.
- Quantity and the date you need the space.
FAQ