Flex-L ADA office pod with the door open and a wheelchair user working at the table inside

Wheelchair accessible office pods

ADA Office Pods with Roll-In Entry for Wheelchair Users

Flex-L ADA and Flex-XL ADA are built without a pod floor. The walls stand on your finished floor, so a wheelchair user rolls straight in through a 35.4-inch clear door and has room to turn around inside.

For meetings of more than six people, the Aura Room-in-Room meeting room is also floorless, from 3 × 3 m upward.

No pod floorRoll in at floor level
35.4 in door900 mm clear opening
60 in turning circleFits inside both sizes
36-40 dBOffice-tested sound level difference

Quick answer

For a wheelchair user, an office pod has to provide step-free entry, a door with at least 32 inches of clear width, and a 60-inch turning space inside, the core room dimensions in the 2010 ADA Standards. B&H Ergonomics builds two floorless sizes that meet them: Flex-L ADA (86.6 × 66.9 in footprint, 2–4 people) and Flex-XL ADA (98.4 × 86.6 in, 4–6 people), each with a 35.4-inch clear door and one wheelchair position among the seats. For meetings of more than six people, choose an Aura Room-in-Room in 3 × 3, 4 × 4, or 5 × 4 m.

ADA pod sizes

Flex-L ADA and Flex-XL ADA dimensions and seating

Both models are Flex Series pods built to order without a floor. Use the exterior size to place the pod on your floor plan and the interior floor size to check turning space and furniture. Flex-L ADA, the smaller size, also works as a single-user ADA privacy booth for calls and focused work.

SpecificationFlex-L ADAFlex-XL ADA
Exterior (W × D × H)86.6 × 66.9 × 88.6 in (2200 × 1700 × 2250 mm)98.4 × 86.6 × 88.6 in (2500 × 2200 × 2250 mm)
Interior floor (W × D)81.3 × 61.6 in (2064 × 1564 mm)93.1 × 81.3 in (2364 × 2064 mm)
Clear door opening35.4 in (900 mm)35.4 in (900 mm)
EntryNo pod floor and no threshold; walls fixed to the finished floorNo pod floor and no threshold; walls fixed to the finished floor
Seating2–4 people, including one wheelchair position4–6 people, including one wheelchair position
Sound privacyIn B&H office testing under controlled conditions, Flex-L ADA showed a 36-40 dB sound level difference.In B&H office testing under controlled conditions, Flex-XL ADA showed a 36-40 dB sound level difference.
Control panel and outletsHeight set to order; recommended 15–48 in above the floorHeight set to order; recommended 15–48 in above the floor

Interior floor sizes are the exterior size minus the 68 mm (2.7 in) Flex wall on each side.

Step-free entry

Roll-in entry with no pod floor

Standard B&H pods stand on their own floor, which adjustable feet raise 40–90 mm (1.6–3.5 in) on the M size. Flex-L ADA and Flex-XL ADA leave that floor out. The walls stand directly on the finished floor and are fixed to it with screws, so the surface inside the pod is the office floor itself, with no threshold at the door.

The 2010 ADA Standards cap a doorway threshold at 1/2 inch (Section 404.2.5). With no pod floor, there is no threshold or ramp to measure.

  • Floor surface: the existing floor becomes the pod floor, so it should be stable, firm, and slip resistant, as Section 302.1 requires.
  • Screw fixing: confirm with the building owner that the floor can take the fixings, especially in a leased office.
  • Door: a 35.4 in (900 mm) clear opening on both models, above the 32 in minimum in Section 404.2.3.
Front view of a floorless Flex-L ADA pod with the office floor running through the open door to the table
Product visualization of Flex-L ADA: the office floor runs straight through the open door to the table, with no threshold or ramp.

Measured against the ADA Standards

How Flex-L ADA and Flex-XL ADA measure against the 2010 ADA Standards

The 2010 ADA Standards for Accessible Design set the dimensions an accessible room is reviewed against. The table compares the ones that apply inside and at the door of a pod.

ADA requirementSectionFlex-L ADAFlex-XL ADA
Door clear width: 32 in minimum404.2.335.4 in35.4 in
Turning space: 60 in circle, or a T-shape within a 60 in square304.361.6 in interior depth; the circle fits with about 0.8 in to spare on each side81.3 in interior depth
Threshold: 1/2 in maximum404.2.5None; no pod floorNone; no pod floor
Controls and outlets: 15–48 in above the floor308.2.1, 308.3.1Height set to orderHeight set to order
Wheelchair space: 30 × 48 in clear floor space305.3Marked at the table on the layout drawingMarked at the table on the layout drawing
Flex-L ADA interior floor with a 60-inch turning circle Top view at 0.3 drawing units per millimeter. Exterior 2200 by 1700 millimeters, 68 millimeter walls, interior floor 2064 by 1564 millimeters. A 1525 millimeter turning circle is centered in the interior with about 20 millimeters to spare on each side of the depth. A 900 millimeter clear door opening is shown on the front wall; its final position follows the project drawing. INTERIOR WIDTH 2064 mm / 81.3 in INTERIOR DEPTH 1564 mm / 61.6 in 60 in / 1525 mm turning circle Section 304.3.1 Door 900 mm / 35.4 in clear About 0.8 in to spare on each side of the circle No pod floor Walls fixed to the finished floor 68 mm Flex walls Exterior 2200 × 1700 mm 86.6 × 66.9 in Roll-in entry No threshold at the door
Planning diagram of the Flex-L ADA interior floor, drawn to scale. Section 304.3.1 lets the circle include knee and toe clearance under a table; other furniture stays outside it. Door position, door swing, and furniture are confirmed on the project drawing. On mobile, scroll the diagram sideways for detail.

Need a different footprint?

Flex ADA pods are built to order. Send the space you have, and B&H Ergonomics will size the pod around the turning circle and door clearance.

Size My ADA Pod

Inside the pod

Sound privacy, controls, and comfort

The floorless build changes the entry. The rest of the pod is specified like any Flex Series pod.

Sound privacy

In B&H office testing under controlled conditions, Flex-L ADA and Flex-XL ADA each showed a 36-40 dB sound level difference.

Control panel and outlets

Heights are set to your order. B&H Ergonomics recommends placing them 15–48 in above the floor, the forward and side reach range in Sections 308.2.1 and 308.3.1.

Power

110V Plug & Play power with UL Listed Components.

Light and air

Built-in LED lighting and ventilation fans.

Finishes

Choose from 9 standard exterior colors or a custom exterior from 216 RAL colors, plus 48 interior colors in fabric or easy-clean laminated steel.

Warranty

A 3-year limited warranty overall. Ventilation fans are covered for 2 years, and electrical components and LED lighting for 1 year.

For larger teams

Aura Room-in-Room: wheelchair accessible meeting rooms for larger teams

When a meeting group is larger than six, a meeting room fits better than a pod. Aura Room-in-Room is a glass-walled meeting room from the B&H Ergonomics Aura Series, shaped with large-radius rounded corners. Like the Flex ADA pods, it has no floor of its own: it stands directly on the office floor, so wheelchair users roll in at floor level.

SizeFootprintTypical use
3 × 3 m9 ft 10 in × 9 ft 10 inFocus room or small huddle room
4 × 4 m13 ft 1 in × 13 ft 1 inTeam collaboration and meetings
5 × 4 m16 ft 5 in × 13 ft 1 inLarger teams, workshops, and multi-use meetings
  • Height: 88.6 in (2250 mm), with a full-height 88.6 in door.
  • Sound: 32 dB sound reduction in every size.
  • Turning space: even the 3 × 3 m size leaves far more floor than a 60-inch turning circle needs.
  • Custom sizes: width, depth, and corner radius are built to your floor plan.
  • Built in: ventilation, lighting, and power.

Finishes and layouts are in the Aura Room-in-Room brochure (PDF).

Aura Room-in-Room filmed at the B&H factory: walking in through the door, and the exterior with its rounded corners.

Choose the format

Which accessible format fits your group

Start from the number of people who meet at once, including the wheelchair user.

  • Flex-L ADA

    A wheelchair user plus up to three people: calls, focus work, one-to-one meetings, and small reviews. The 86.6 × 66.9 in footprint fits where a meeting room will not.

  • Flex-XL ADA

    Four to six people, including one wheelchair position. The 93.1 × 81.3 in interior leaves more floor beyond the turning circle for a table and chairs.

  • Aura Room-in-Room

    Groups larger than six, workshops, or a room shaped to an unusual floor plan, in 3 × 3, 4 × 4, or 5 × 4 m or a custom size.

Project review

What your ADA review will check around the pod

Accessibility is reviewed for the installed space, including the route to the pod and the furniture inside it. Bring these points to your architect or the authority having jurisdiction (AHJ).

  1. Route to the door

    Keep an accessible route at least 36 in wide to the pod (Section 403.5.1).

  2. Door approach

    Leave maneuvering clearance on both sides of the door for the approach direction and door swing (Section 404.2.4).

  3. Turning space

    Keep the 60 in circle or T-shaped space clear inside once the furniture is placed (Section 304.3).

  4. Table and seating

    Choose a work surface 28–34 in high (Section 902.3), with a 30 × 48 in clear floor space at the table (Section 305.3).

  5. Controls and outlets

    Set the control panel and outlets 15–48 in above the floor (Section 308).

  6. Fire, electrical, and air

    Check sprinkler, electrical, and ventilation requirements with the guide to office pod fire safety, UL documentation, and AHJ review.

For the background on turning circles, T-turns, and accessible meeting layouts, see what makes an ADA room accessible.

ADA pod quote

Request an ADA pod quote

Tell B&H Ergonomics who will use the space and where it will stand. The quote confirms the model, size, furniture, and control heights for your project.

Delivered DDP to the Lower 48 states, with 110V Plug & Play power and UL Listed Components.

Request an ADA Pod Quote

Include these details

  • City and state for delivery.
  • Number of users and wheelchair positions.
  • Floor plan, or the available width and depth.
  • Flex-L ADA, Flex-XL ADA, or an Aura Room-in-Room size.
  • Quantity and the date you need the space.

FAQ

ADA office pod questions

Are these pods ADA compliant?
Flex-L ADA and Flex-XL ADA are built to the room dimensions in the 2010 ADA Standards: a 35.4-inch clear door, step-free entry with no pod floor, and room for a 60-inch turning circle. ADA compliance applies to the installed space as a whole, including the route, furniture, and controls, and is confirmed in your project’s accessibility review.
Can one person use an ADA pod as a phone booth?
Yes. Flex-L ADA works as a single-user ADA phone booth or privacy booth, with the full turning circle around a wheelchair user taking calls or video meetings.
Can an ADA pod be built to another size?
Yes. Flex ADA pods and Aura Room-in-Room are built to order, so the width, depth, and control heights can follow your floor plan.
How is a floorless pod fixed in place?
The walls stand on the finished floor and are fixed to it with screws. Confirm with the building owner that the floor can take the fixings before you choose the location.

Request Your Office Pod Quote

Trade & volume pricing available

Ordering 5+? Tell us how many below.